CVE-2026-5773

libcurl might in some circumstances reuse the wrong connection for SMB(S) transfers. libcurl features a pool of recent connections so that subsequent requests can reuse an existing connection to avoid overhead. When reusing a connection a range of criteria must be met. Due to a logical error in the code, a network transfer operation that was requested by an application could wrongfully reuse an existing SMB connection to the same server that was using a different "share" than the new subsequent transfer should. This could in unlucky situations lead to the download of the wrong file or the upload of a file to the wrong place. When this happens, the same credentials are used and the server name is the same.

Score
7.5 high
Published
2026-05-13
Links
NVD · cve.org

Affected ports (1)

PortPackageVersionStatusMaintainer
ftp/linux-rl9-curllinux-rl9-curl7.76.1_13unaddressedemulation@FreeBSD.org

Template for a VuXML entry

Range taken from the CVE record, check it before committing. make newentry in security/vuxml creates the vid.

  <vuln vid="FIXME (make newentry)">
    <topic>FIXME -- FIXME</topic>
    <affects>
      <package>
	<name>linux-rl9-curl</name>
	<range><lt>8.20.0</lt></range>
      </package>
    </affects>
    <description>
      <body xmlns="http://www.w3.org/1999/xhtml">
	<p>libcurl might in some circumstances reuse the wrong connection for
	SMB(S)
transfers.

libcurl features a pool of recent connections so
	that subsequent requests can
reuse an existing connection to avoid
	overhead.

When reusing a connection a range of criteria must be met.
	Due to a logical
error in the code, a network transfer operation that
	was requested by an
application could wrongfully reuse an existing SMB
	connection to the same
server that was using a different "share" than
	the new subsequent transfer
should.

This could in unlucky situations
	lead to the download of the wrong file or the
upload of a file to the
	wrong place. When this happens, the same credentials
are used and the
	server name is the same.</p>